Intel® Server Board S2600CW Platform Management  Intel® Server Board S2600CW Family TPS 
60    Revision 2.4 
5.  Intel® Server Board S2600CW Platform 
Management 
Platform management is supported by several hardware and software components integrated 
on the server board that work together to support the following: 
  Control system functions – power system, ACPI, system reset control, system 
initialization, front panel interface, system event log. 
  Monitor various board and system sensors, regulate platform thermals and 
performance in order to maintain (when possible) server functionality in the event of 
component failure and/or environmentally stressed conditions. 
  Monitor and report system health. 
  Provide an interface for Server Management Software applications. 
This chapter provides a high level overview of the platform management features and 
functionality implemented on the server board. 
The Intel® Server System BMC Firmware External Product Specification (EPS) and the Intel® 
Server System BIOS External Product Specification (EPS) for Intel® Server Products based on 
the Intel® Xeon® processor E5-2600 v3 and v4 product families should be referenced for more 
in-depth and design level platform management information. 
5.1  Management Feature Set Overview 
The following sections outline features that the integrated BMC firmware can support. Support 
and utilization for some features is dependent on the server platform in which the server 
board is integrated and any additional system level components and options that may be 
installed. 
5.1.1  IPMI 2.0 Features Overview 
  Baseboard management controller (BMC) 
  IPMI Watchdog timer 
  Messaging support, including command bridging and user/session support 
  Chassis device functionality, including power/reset control and BIOS boot flags 
support 
  Event receiver device: The BMC receives and processes events from other platform 
subsystems. 
  Field Replaceable Unit (FRU) inventory device functionality: The BMC supports access 
to system FRU devices using IPMI FRU commands. 
  System Event Log (SEL) device functionality: The BMC supports and provides access to 
a SEL including SEL Severity Tracking and the Extended SEL.