Intel® Server Board S2600CW Platform Management  Intel® Server Board S2600CW Family TPS 
88    Revision 2.4 
  Warn user the reconfiguration of IP address will cause disconnect 
  Capability to block logins for a period of time after several consecutive failed login 
attempts. The lock-out period and the number of failed logins that initiates the 
lock-out period are configurable by the user. 
  Server Power Control – Ability to force into Setup on a reset 
  System POST results – The web server provides the system’s Power-On Self Test 
(POST) sequence for the previous two boot cycles, including timestamps. The 
timestamps may be viewed in relative to the start of POST or the previous POST code. 
  Customizable ports – The web server provides the ability to customize the port 
numbers used for SMASH, http, https, KVM, secure KVM, remote media, and secure 
remote media. 
For additional information, reference the Intel® Remote Management Module 4 and Integrated 
BMC Web Console Users Guide. 
5.5  Advanced Management Feature Support (RMM4 Lite) 
The integrated baseboard management controller has support for advanced management 
features which are enabled when an optional Intel
®
 Remote Management Module 4 Lite (RMM4 
Lite) is installed. The Intel
®
 RMM4 add-on offers convenient, remote KVM access and control 
through LAN and internet. It captures, digitizes, and compresses video and transmits it with 
keyboard and mouse signals to and from a remote computer. Remote access and control 
software runs in the integrated baseboard management controller, utilizing expanded 
capabilities enabled by the Intel RMM4 hardware. 
Intel
®
 Remote Management Module 
4 Lite 
Key 
Enables KVM & media redirection  
 
When the BMC FW initializes, it attempts to access the Intel
®
 RMM4 lite. If the attempt to 
access the Intel
®
 RMM4 lite is successful, the BMC activates the Advanced features. 
The following table identifies both Basic and Advanced server management features. 
Table 13. Basic and Advanced Server Management Features Overview 
In-circuit BMC Firmware Update 
Chassis Intrusion Detection 
Fan Redundancy Monitoring