Intel® Server Board S2600CW Family TPS Appendix C: BMC Sensor Tables
Revision 2.4
167
Full Sensor Name
(Sensor name in SDR)
Senso
r #
Platform
Applicabili
ty
Sensor Type Event/Rea
ding Type
Event Offset
Triggers
Contrib. To
System
Status
Assert
/De-
assert
Readab
le
Value/
Offsets
Event
Data
Rearm Stand-
by
Processor 4 DIMM Aggregate
Thermal Margin 1
(P4 DIMM Thrm Mrgn1)
B6h
Platform
Specific
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog R, T A
Processor 4 DIMM Aggregate
Thermal Margin 2
(P4 DIMM Thrm Mrgn2)
B7h
Platform
Specific
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog R, T A
Node Auto-Shutdown
Sensor
(Auto Shutdown)
B8h
Multi-
Node
Specific
Power Unit
09h
Generic
digital
discrete
03h
01 State Asserted Non-fatal
As
and
De
- Trig Offset A -
Fan Tachometer Sensors
(Chassis specific
sensor names)
BAh
BFh
Chassis
and
Platform
Specific
Fan
04h
Threshold
01h
[l] [c,nc]
nc =
Degraded
c = Non-fatal
2
As
and
De
Analog R, T M -
Processor 1 DIMM
Thermal Trip
(P1 Mem Thrm Trip)
C0h All
Memory
0Ch
Sensor
Specific
6Fh
0A- Critical
overtemperature
Fatal
As
and
De
Trig Offset M -
Processor 2 DIMM
Thermal Trip
(P2 Mem Thrm Trip)
C1h All
Memory
0Ch
Sensor
Specific
6Fh
0A- Critical
overtemperature
Fatal
As
and
De
Trig Offset M -
Processor 3 DIMM
Thermal Trip
(P3 Mem Thrm Trip)
C2h
Platform
Specific
Memory
0Ch
Sensor
Specific
6Fh
0A- Critical
overtemperature
Fatal
As
and
De
Trig Offset M X
Processor 4 DIMM
Thermal Trip
(P4 Mem Thrm Trip)
C3h
Platform
Specific
Memory
0Ch
Sensor
Specific
6Fh
0A- Critical over
temperature
Fatal
As
and
De
Trig Offset M X
MIC 1 Temp
(GPGPU1 Core Temp)
C4h
Platform
Specific
Temperature
01h
Threshold
01h
- - - - - - -

Table of Contents

Other manuals for Intel S2600CW