Goodrive300-01A-RT series integrated machine RS485 communication LCD keypad
-111-
03.17 16:02:35
Home
Timing switch setting
Return Edit
User param
Sleep Function Enable
Load/Unload Mode Automatic
Power consumption xxxx.x kW.h
Accumlated Run Time xxxxxx h
Restart Delay xxxxxx s
Figure B-12 User parameter interface
Constant exhaust temperature that is set for constant
temperature control on fan.
When the exhaust temperature is lower than this value, the
fan is stopped.
When the exhaust temperature is higher than this value, the
fan is started.
After the startup, the air compressor runs with load with this
specified delay.
If the manual mode is used, both load and unload need to be
manually performed after the air compressor is started.
If the automatic mode is used, the air compressor
automatically loads or unloads depending on the pressure
after being started.
Max. continuous empty-load running time allowed by the air
compressor. If the time is reached, the air compressor
enters the sleep state.
Before stop, the device runs at the empty-load frequency
and stops with this specified delay.
After the device stops, the device determines whether to
start with this specified delay.
Air supply pressure during stable running. The VFD controls
the running frequency according to this pressure so as to
implement constant pressure for air supply.
If the pressure is higher than this value when the air
compressor is running, the VFD controls the air compressor
to run without load.