Goodrive300-01A-RT series integrated machine Function description
-34-
Function
code
Name
Description
Default
Modify
P01.19
Action selected when
running frequency less
than frequency lower
limit (valid when
frequency lower limit
greater than 0)
0: Run at the frequency lower limit
0
P01.21
Power-off restart
selection
0: Disable
1: Enable
0
P01.22
Wait time for restart
after power-off
0.03600.0s (valid when P01.21=1)
1.0s
P01.23
Start delay
0.060.0s
0.0s
P01.24
Stop speed delay
0.0100.0 s
0.0s
P01.25
0Hz output
0: Output without voltage
1: Output with voltage
2: Reserved
0
P02 group Motor 1 parameters
Function
code
Name
Description
Default
Modify
P02.00
Type of motor 1
0: Asynchronous motor (AM)
0
P02.01
Rated power of AM 1
0.13000.0kW
Model
depended
P02.02
Rated frequency of AM
1
0.01HzP00.03 (max. output frequency)
50.00Hz
P02.03
Rated speed of AM 1
136000rpm
Model
depended
P02.04
Rated voltage of AM 1
01200V
Model
depended
P02.05
Rated current of AM 1
0.86000.0A
Model
depended
P02.06
Stator resistance of AM
1
0.001–65.535Ω
Model
depended
P02.07
Rotor resistance of AM
1
0.001–65.535Ω
Model
depended
P02.08
Leakage inductance of
AM 1
0.16553.5mH
Model
depended