Goodrive300-01A-RT series integrated machine Function description
-72-
Function
code
Name
Description
Default
Modify
When the output current is larger than
automatic frequency reduction threshold, it
will adjust the output frequency via regulator
to ensure the running current of the master is
below the automatic frequency reduction
threshold.
P18.45
Maintenance timeout
time
08000h
When it is set to 0”, maintenance timeout
function will be invalid. When it is set to a
non-zero value, after parts maintenance
pre-alarm is reported, if the VFD continues
working until exceeding the value set by
P18.45, the system will report maintenance
timeout pre-alarm, and BIT11 of P19.14 will
be set to “1”.
0
P19 group Air compressor status viewing
Function
code
Name
Description
Default
Modify
P19.00
The set time of
maintenance on part 1
P19.00P19.04 displays the set time of
maintenance on five kinds of parts. If the
accumulated running time of the part
exceeds the corresponding set value, the
BIT of P19.14 will be set to 1 to indicate
pre-alarms; if it is set to “0”, the running
time pre-alarm will be invalid.
P19.05P19.09 displays the running time
of corresponding parts.
Range: 065535h
0
P19.01
The set time of
maintenance on part 2
0
P19.02
The set time of
maintenance on part 3
0
P19.03
The set time of
maintenance on part 4
0
P19.04
The set time of
maintenance on part 5
0
P19.05
Running time of part 1
0
P19.06
Running time of part 2
0
P19.07
Running time of part 3
0
P19.08
Running time of part 4
0
P19.09
Running time of part 5
0

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVT Goodrive300-01A-RT Series and is the answer not in the manual?

INVT Goodrive300-01A-RT Series Specifications

General IconGeneral
BrandINVT
ModelGoodrive300-01A-RT Series
CategoryInverter
LanguageEnglish

Related product manuals