Goodrive300-01A-RT series integrated machine Function description
-73-
Function
code
Name
Description Default Modify
P19.10
Actual output power of
the motor
Display output power of the motor, it can be
calibrated by P18.22.
Range: 0.06553.5kW
0.0kW
P19.11
Present pressure
Display the discharge pressure value
detected currently.
Range: 0.00655.35Mpa
0.00Mpa
P19.12
Present temperature
Display the machine head temperature
detected currently.
e
Range: -20150
0
P19.13
Signal state 1
00000xFFFF
00000xFFFF
BIT0: Air filter blockage signal
1: Fault; 0: Normal
BIT1: Oil filter blockage signal
1: Fault; 0: Normal
0
P05.32
P05.34
0
P18.04
P17.19
P1 input
voltage
Present
pressure
Mpa
P19.11
P18.37=0
P18.28
0
150
P17.20
-20
PT1 input voltage
Present auxiliary temperature
P18.29
P18.32
0
150
P17.22
-20
PT2 input voltage
P
resent auxiliary temperature
P18.33
P18.03=0
P18.03=1
20
120
20
120
P19.12
P19.12

Table of Contents