Goodrive300-01A-RT series integrated machine Function description
-74-
Function
code
Name
Description
Default
Modify
BIT2: Separator blockage signal
1: Fault; 0: Normal
BIT3: Precision splitter blockage signal
1: Fault; 0: Normal
BIT4: External fault signal 1
1: Fault; 0: Normal
BIT5: External fault signal 2
1: Fault; 0: Normal
BIT6: Solenoid valve signal state
1: Load; 0: Unload
BIT7: Fan state
1: Run; 0: Stop
BIT8: Pressure pre-alarm signal
1: Pressure pre-alarm; 0: Normal
BIT9: Temperature pre-alarm signal
1: Temperature pre-alarm; 0: Normal
BIT10: Pressure alarm signal
1: Pressure alarm; 0: Normal
BIT11: Temperature alarm signal
1: Temperature alarm; 0: Normal
BIT12: Pressure signal
1: Pressure signal fault; 0: Normal
BIT13: Temperature signal
1: Temperature signal fault; 0: Normal
BIT14: Low-temperature protection
1: Low-temperature alarm; 0: Normal
BIT15: Master state
1: Run; 0: Stop
P19.14
Signal state 2
00xFFFF
BIT0: Maintenance reminder of part 1
1: Maintenance required; 0: Normal
BIT1: Maintenance reminder of part 2
1: Maintenance required; 0: Normal
BIT2: Maintenance reminder of part 3
1: Maintenance required; 0: Normal
BIT3: Maintenance reminder of part 4
1: Maintenance required; 0: Normal
BIT4: Maintenance reminder of part 5
0