Goodrive300-01A-RT series integrated machine Function description
-39-
Function
code
Name
Description
Default
Modify
P03.20
Electromotive torque
upper limit set through
keypad
0.0300.0% (of the motor rated current)
180.0%
P03.21
Braking torque upper
limit set through
keypad
0.0300.0% (of the motor rated current)
180.0%
P03.22
Weakening coefficient
in constant power zone
0.12.0
0.3
P03.23
Lowest weakening
point in constant power
zone
10%100%
20%
P03.24
Max. voltage limit
0.0120.0%
100.0%
P03.25
Pre-exciting time
0.00010.000s
0.300s
P03.26
Flux-weakening
proportional gain
08000
300
P03.27
Speed display
selection in vector
control
0: Display the actual value
1: Display the set value
0
P04 group SVPWM control
Function
code
Name
Description
Default
Modify
P04.00
V/F curve setting of
motor 1
0: Straight-line V/F curve
0
P04.01
Torque boost of motor
1
0.0%: (automatic); 0.1%10.0%
0.0%
P04.02
Torque boost cut-off of
motor 1
0.0%50.0% (relative to rated frequency of
motor 1)
20.0%
P04.03
V/F frequency point 1
of motor 1
0.00HzP04.05
0.00Hz
P04.04
V/F voltage point 1 of
motor 1
0.0%110.0% (of the rated voltage of motor
1)
00.0%
P04.05
V/F frequency point 2
of motor 1
P04.03 P04.07
00.00Hz
P04.06
V/F voltage point 2 of
motor 1
0.0%110.0% (of the rated voltage of motor
1)
00.0%

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVT Goodrive300-01A-RT Series and is the answer not in the manual?

INVT Goodrive300-01A-RT Series Specifications

General IconGeneral
BrandINVT
ModelGoodrive300-01A-RT Series
CategoryInverter
LanguageEnglish

Related product manuals