Goodrive300-01A-RT series integrated machine Function description
-40-
V/F frequency point 3
of motor 1
P04.05–P02.02 (rated frequency of AM 1)
/P04.05–P02.16 (rated frequency of SM 1)
V/F voltage point 3 of
motor 1
0.0%–110.0% (of the rated voltage of motor
1)
V/F slip compensation
gain of motor 1
Low-frequency
oscillation control
factor of motor 1
High-frequency
oscillation control
factor of motor 1
Oscillation control
threshold of motor 1
0.00Hz–P00.03 (max. output frequency)
0: Disable
1: Automatic energy-saving run
Weakening coefficient
in constant power zone
Reactive closed-loop
proportional coefficient
0–3000
When the SM V/F control mode is enabled,
the function code is used to set the
proportional coefficient of the reactive
current closed-loop control.
Reactive closed-loop
integral coefficient
0–3000
When the SM V/F control mode is enabled,
the function code is used to set the integral
coefficient of the reactive current closed-loop
control.