-112-
If the VFD detects the pressure is lower than this value when
the air compressor is running without load, the VFD controls
the air compressor to run with load. If the VFD detects the
pressure is lower than this value when the air compressor is
sleeping, the master is waken up.
All the electricity consumption (kWh) of the VFD system.
The value is automatically generated and cannot be set, but
it can be cleared.
Accumulative running time (hours) of the VFD system. The
value is automatically generated and cannot be set, but it
can be cleared.
Press “Set” to access the corresponding interface.
Startup time: Scheduled time when the device is
automatically started.
Shutdown time: Scheduled time when the device is
automatically stopped.
Startup action: Disable/enable (Timed startup is valid only in
Enabled state. Otherwise, the device is not automatically
started even though the scheduled startup time has been
set.)
Shutdown action: Disable/enable (Timed stop is valid only in
Enabled state. Otherwise, the device is not automatically
stopped even though the scheduled shutdown time has
been set.)
2. In the user parameter interface, you can edit parameters only after entering the correct user
password.
03.17 16:02:35
Home
Please enter current password:
Return Confirm
000
0
Figure B-13 User password input interface