6-14
Capter 6 Adjust Mode
6.7 Calibration
Menu name Specification
CAPACITY Select the capacity of the scale.
6000g / 6kg / 15kg / 30kg / 30lb
RANGE Select the range.
SINGLE / MULTI
The range to be selected is limited depending on the capacity.
GRAVITATIONAL
ACC.
Enter the gravitational acceleration.
Input range: 97799 to 98300
DATA DISPLAY Select the A/D or cell voltage display.
WEIGHT / VOLTAGE
INITIAL Initialize the scale.
ZERO Enter the current scale status to zero.
SPAN Enter the current scale status to CAPACITY according to CAPACITY
setting.
+ Add span value.
- Deduct span value.