5-3
Chapter 5 Setup Mode
5.2 Machine No. setting
5.2.1 Basic
5.2.1.1 Alone
Menu name Specification
MACHINE No. Enter the machine number.
Input range: 1 to 99
NETWORK No. Enter the network number.
Input range: 1 to 9
MACHINE SET Select one of the stand-alone, master or satellite machines.
ALONE / MASTER / SAT.
This function is enabled only when you log into the service network.
The confirmation dialog appears when ALONE, MASTER and SAT.
are selected respectively.