Error Messages
Error
Code
Error Message Description
-168 Block data not allowed The data type is not allowed to
be block data.
-170 Expression error The expression is incorrect.
-171 Invalid expression Invalid expression.
-178 Expression data not allowed Expression data is not allowed.
command execution related errors
-200 Execution error [generic] If the status or setting of the
command is incorrect, the error
will be reported. For example,
*TRG must be executed when
the LIST trigger source is set to
BUS, so executing *TRG will
prompt the error when the LIST
trigger source is set to Manual.
-221 Settings conflict [check current
device state]
A data element could not be
executed because of the
present instrument state.
-222 Data out of range [e.g., too
large for this device]
A data element could not be
executed because the value
was outside the valid range.
-223 Too much data [out of memory;
block, string, or expression too
long]
A data element was received
that contains more data than
the instrument can handle.
-224 Illegal parameter value [de-
vice-specific]
An exact value was expected
but not received.
-225 Out of memory The device has insufficient
memory to perform the re-
quested operation.
-230 Data Corrupt or Stale Possible invalid data. A new
reading was started but not
completed.
-270 Macro error Macro definition error.
-272 Macro execution error Macro execution error
-273 Illegal macro label Illegal macro tag
Copyright © Itech Electronic Co., Ltd.