Maintenance
Electrical System
Electrical System
General
Check (Operation)
Make sure all of the electrical equipment operates correctly, for example:
Switches
Warning lights
Beacon
Alarms
Horn
Wipers
Hourmeter/display
12V battery
Lights
All defective equipment must be repaired before the machine is used.
Check (Condition)
Examine the electrical circuits regularly for:
Damaged connectors
Loose connections
Chafing on the wiring harnesses
Corrosion
Missing insulation
Incorrect routing of the wiring harnesses.
Do not use the machine if one or more of these faults are found. You must make sure that the electrical circuit
is repaired immediately.
Battery
Clean
12V Battery
WARNING Keep metal watch straps and any metal fasteners on your clothes, clear of the positive (+)
battery terminal. Such items can short between the terminal and nearby metal work. If it happens you can
get burned.
1. Make the machine safe.
Refer to: Maintenance Positions (Page 116).
2. Get access to the battery.
Refer to: Access Apertures (Page 119).
3. If the terminal posts are corroded and covered with white powder wash them with hot water. If there is
considerable corrosion, clean the terminal posts with a wire brush or abrasive paper. Refer to Figure 108.