EasyManuals Logo
Home>jcb>Compact Excavator>19C-1E

jcb 19C-1E User Manual

jcb 19C-1E
180 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #168 background imageLoading...
Page #168 background image
Technical Data
Electrical System
Electrical System
General
General
Table 21.
Item Specification
Motor Type AC Permanent Magnet
Motor Power 7kW
continuous
20kW
peak
Operating Modes L-1200 rpm
G-1600 rpm
H-1800 rpm
Auto Kick Up-2300 rpm, 2 speed tracking only
12V Battery
Table 22.
Item Specification
Battery voltage 12V
Capacity 65Ah
12V
CCA (Cold Cranking Amps) 620
Hazardous Voltage Batteries
Table 23.
Item Specification
System voltage 48V
Cell chemistry Manganese laminated Lithium-ion
Gross capacity (3-battery pack machine) 14.82kWh
Gross capacity (4-battery pack machine) 19.76kWh
Charging On-board charger, with direct connection from AC
mains power supply
Charging Time 110V
=
12h
230V
=
8h
Fast Charging (Optional) Off-board charger, with connection to 415V, 3 Phase
supply. Charging time, 2h
Thermal Limitations Operation:-10°C (14.0°F) to 46°C (114.7°F)
Charging:-10°C (14.0°F) to 40°C (103.9°F)
158 9831/8250-4 158
JCB © Admin Pimteam - 23/06/2021 05:32.

Table of Contents

Other manuals for jcb 19C-1E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the jcb 19C-1E and is the answer not in the manual?

jcb 19C-1E Specifications

General IconGeneral
Battery TypeManganese laminated Lithium-ion
Battery Rated Capacity14.8 kWh (3 Pack) 19.8 kWh (4 Pack)
ChargingOn-board charger with direct connection from AC mains power supply
Charging Time110V – 12 hrs 230V – 8 hrs
Fast Charging (Optional)Off-board charger, with connection to 415V 3-Phase supply Charging time <2 hrs
System Voltage48V
Motor TypeAC permanent magnet
Motor Power7 kW continuous 20kW peak
Operating ModesL – 1200rpm G – 1600rpm H – 1800rpm Auto Kick Up – 2300rpm, 2 speed tracking only
Thermal LimitationsOperation: -10oC to +46oC Charging: -10oC to +40oC

Related product manuals