Appendix A Test Results
OAM results
HST-3000 Ethernet Testing Users Guide
285
Table 29 describes the Link Layer OAM Remote Op Mode
results. The Link OAM State must be On to observe these
results.
Max PDU Size Displays the maximum PDU (Protocol
Data Units) size supported by the local
instrument.
Unidirectional Indicates whether the local instrument
advertises that it provides unidirectional
support for failure detection.
Link Events Indicates whether the local instrument
is configured to monitor link events.
Local Loopback Indicates whether the local instrument
advertises that it provides loopback
support.
Variable Retrieval Indicates whether the local instrument
supports sending Variable Response
OAM PDUs.
Revision Displays the current of the TLV (Type
Length Value) revision for the local
instrument.
Table 29 L-OAM Remote Op Mode test results
Result Description
Mode Displays the current mode (Active or
Passive) for the instrument’s peer.
Parser Action Indicates the remote receiver is cur-
rently forwarding, looping back, or dis-
carding non-OAM PDUs.
Muxer Action Indicates the remote transmitter is cur-
rently forwarding or discarding
non-OAM PDUs.
Table 28 L-OAM Local Op Mode test results (Continued)
Result Description

Table of Contents