Table 39: Chassis Alarm Messages
Recommended ActionCLI MessageAlarm TypeComponent
Replace the fan module and report the
failure to customer support.
Fan FailureMajor (red)Fans
Check the system log for one of the
following error messages and report the
message to customer support:
•
CM ENV Monitor: Get fan speed failed.
•
fan-number is NOT spinning @ correct
speed, where fan-number can be 1, 2, 3,
4, or 5.
Fan I2C Failure
Remove and check the fan module for
obstructions, and then reinsert the fan
module. If the problem persists, replace
the fan module.
Fan fan-number Not Spinning
Check the system log for the error
message fan-number Absent, where
fan-number can be can be 1, 2, 3, 4, or 5.
Install fan modules in the slots where
they are absent.
Fan/Blower AbsentMinor (yellow)
127Copyright © 2019, Juniper Networks, Inc.
Chapter 5: Troubleshooting Hardware

Table of Contents

Other manuals for Juniper QFX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper QFX Series and is the answer not in the manual?

Juniper QFX Series Specifications

General IconGeneral
CategorySwitch
SeriesQFX
Form Factor1U, 2U, and modular chassis options
Power SupplyRedundant, hot-swappable power supplies
Coolinghot-swappable fans
Virtual ChassisSupported on certain models
Typical UseData center, cloud
Operating SystemJunos OS
ManagementCLI
Key FeaturesHigh performance, low latency, automation
LatencySub-microsecond latency
Port DensityVaries by model (e.g., QFX5100: up to 48x10GbE + 6x40GbE)

Related product manuals