switch continues to operate with only one power supply running. Replace a
failed fan module with a new fan module within one minute of removal to
prevent chassis overheating. Do not operate the switch with missing FRUs
for longer than one minute.
Table 4 on page 26 lists the FRUs for the QFX5110 and actions to take before removing
them.
Table 4: FRUs in a QFX5110
Required ActionFRU
None.Power supplies
None.Fan modules
None. We recommend that you disable the interface using the set interfaces
interface-name disable command before you remove the transceiver. See “Removing
a Transceiver on page 113.
Optical transceivers
NOTE: If you have a Juniper Care service contract, you can register any
addition, change, or upgrade of hardware components at
https://www.juniper.net/customers/support/tools/updateinstallbase/. Failure
to do so can result in significant delays if you need replacement parts. This
note does not apply if you replace existing components with the same type
of component.
See Also Maintaining QFX5110 Fan Modules on page 107
Maintaining QFX5110 Power Supplies on page 110
Removing and Installing Transceivers and Fiber-Optic Cables on QFX5110 on page 113
Related
Documentation
QFX5110 Management Panel on page 34
QFX5110 Port Panels on page 26
QFX5110 Port Panels
QFX5110-48S Port Panel on page 27
QFX5110-32Q Port Panel on page 29
QFX5110 Network Port LEDs on page 32
Copyright © 2019, Juniper Networks, Inc.26
QFX5110 Switch Hardware Guide

Table of Contents

Other manuals for Juniper QFX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper QFX Series and is the answer not in the manual?

Juniper QFX Series Specifications

General IconGeneral
CategorySwitch
SeriesQFX
Form Factor1U, 2U, and modular chassis options
Power SupplyRedundant, hot-swappable power supplies
Coolinghot-swappable fans
Virtual ChassisSupported on certain models
Typical UseData center, cloud
Operating SystemJunos OS
ManagementCLI
Key FeaturesHigh performance, low latency, automation
LatencySub-microsecond latency
Port DensityVaries by model (e.g., QFX5100: up to 48x10GbE + 6x40GbE)

Related product manuals