Figure 2: Rear Panel Components of the AC Variant of the SRX1600
Table 6 on page 14 lists and describes the rear panel components of the AC variant of the SRX1600.
Table 6: Components on the Rear Panel of the AC Variant of the SRX1600 Firewall
Callout Component Descripon
1 Grounding point Grounding point
2 Fan modules Three airow out (AFO) fan modules
(2+1 redundancy).
Two fan modules provide airow across
the internal components of the chassis.
The third fan module provides
redundancy.
3 ESD ESD socket
4 PSU The SRX1600 has a 450 W AC PSU.
5 Empty PSU slot The SRX1600 has a blank slot to install
an addional PSU (1+1 redundancy).
NOTE: We ship the SRX1600 with only one PSU. You can order the second PSU separately, if
required.
You must not mix AC and DC power supplies in the same chassis.