Table 15: AC Power Specicaons for SRX1600
Item Specicaon
AC input voltage Operang range: 100–127 VAC / 200–240 VAC
AC input line frequency 50–60 Hz
AC input current rang 5.5 A at 100–127 VAC
3 A at 200–240 VAC
Maximum power consumpon 450 W
Average power consumpon 137 W at 110 VAC
130.5 W at 230 VAC
You must use a dedicated external circuit breaker for each PSU. We recommend that you use a 10 A
(250 VAC), or as permied by the local code.
Supported AC Power Cords
WARNING: Use the AC power cord with the rewall only and not for any other
purpose.
NOTE: In North America, AC power cords must not exceed a length of 4.5 m (approximately
14.75 ). This length complies with Naonal Electrical code (NEC) Secon 400-8 (NFPA 75,
5-2.2) and 210-52, and Canadian Electrical Code (CEC) Secon 4-010(3).
Table 15 on page 25 provides power cord specicaons, and Figure 11 on page 26 depicts the plug on
the AC power cord provided for each country or region.