11-2 Common Commands Model 6485 Picoammeter Instruction Manual
Common Commands
Common commands (summarized in Table 11-1) are device commands that are common
to all devices on the bus. These commands are designated and dened by the IEEE-488.2
standard.
Table 11-1
IEEE-488.2 common commands and queries
Mnemonic Name Description Ref
*CLS Clear status Clears all event registers and error queue. Section 10
*ESE <NRf> Event enable command Program the standard event enable register. Section 10
*ESE? Event enable query Read the standard event enable register. Section 10
*ESR? Event status register query Read the standard event enable register and clear
it.
Section 10
*IDN? Identication query Returns the manufacturer, model number, serial
number, and rmware revision levels of the unit.
A
*OPC Operation complete command Set the operation complete bit in the standard
event register after all pending commands have
been executed.
B
*OPC? Operation complete query Places an ASCII 1 into the output queue when
all pending selected device operations have been
completed.
B
*OPT? Option query Returns model number of any installed options.
*RCL <NRf> Recall command Returns Model 6485 to the user-saved setup. C
*RST Reset command Returns Model 6485 to the *RST default
conditions.
D
*SAV <NRf> Save command Saves the present setup as the user-saved setup. C
*SRE <NRf> Service request enable command Programs the service request enable register. Section 10
*SRE? Service request enable query Reads the service request enable register. Section 10
*STB? Status byte query Reads the status byte register. Section 10
*TRG Trigger command Sends a bus trigger to Model 6485. E
*TST? Self-test query Performs a checksum test on ROM and returns
the result.
F
*WAI Wait-to-continue command Wait until all previous commands are executed. G

Table of Contents

Other manuals for Keithley 6485

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 6485 and is the answer not in the manual?

Keithley 6485 Specifications

General IconGeneral
ModelKeithley 6485
CategoryPicoammeter
Input Impedance>10^14 Ohms
Voltage Burden<200µV
Accuracy0.4% of reading
Voltage Source RangeNot Applicable
Voltage Source ResolutionNot Applicable
Voltage Source AccuracyNot Applicable
InterfaceIEEE-488
Power Requirements100V to 240V AC, 50/60Hz
Dimensions89 mm high x 214 mm wide x 369 mm deep (3.5 in x 8.4 in x 14.5 in)