[:SOURce]:INTerference[:LEVel]:CMODe:SOURce[?]
Syntax [:SOURce]:INTerference[:LEVel]:CMODe:SOURce ‘identifier’,
<HFRequency|LFRequency>
[:SOURce]:INTerference[:LEVel]:CMODe:SOURce? ‘identifier’
Input
Parameters
‘identifier’: ‘M*.DATAOUT1’ or ‘M*.DataOut2’
<HFRequency|LFRequency>: Select HF or LF generator.
Return Range HFR|LFR
Description This command selects the high frequency or low frequency generator type
for common mode interference.
This SCPI is applicable for M8041A and M8051A.
Example :INT:CMOD:SOUR ‘M2.DataOut1’, HFR
[:SOURce]:INTerference[:LEVel]:CMODe:GAIN[?]
Syntax [:SOURce]:INTerference[:LEVel]:CMODe:GAIN ‘identifier’, <NRf>
[:SOURce]:INTerference[:LEVel]:CMODe:GAIN? ‘identifier’
Input
Parameters
‘identifier’: ‘M*.DATAOUT1’ or ‘M*.DataOut2’
<NRf>: Set common mode interference gain.
Return Range 0.1 to 1.0
Description This command sets the linear gain of the common mode interference.
This command is only for M8061A and M8062A.
Example :INT:CMOD:GAIN ‘M2.DataOut1’, 0.5