Keysight M8070A Programming Guide 333
SCPI Command Reference 5
One Bits, Compared Zero Bits, Errored One Bits, Errored Zero Bits, Sample
Delay and Pass/Fail Results and are repeated in the same order for
subsequent measured points.
In the case of Sample Delay Optimization as "None" the pass/fail result for
each measurement point is returned as "UNKNOWN". However if the Fast
Total Jitter Measurement is performed then the Pass/Fail results could be
either "PASS", "FAIL" or "UNKNOWN"
If the location is omitted from the above example e.g. if the query is
:PLUG:OTIM:FETC:DATA? ‘Output Timing 1’ then the query returns the
comma separated list of all the analyzer location group participating in the
measurement
(("M1.DataIn1",1420788572.96819,499999011,500000989,249999011,25
0000000,-0.6035,"UNKNOWN", ...),
("M1.DataIn2",1420788572.96819,499999011,500000989,249999011,250
000000,-0.6035,"UNKNOWN",))
:PLUGin:OTIMing:FETCh:DELay?
Syntax :PLUGin:OTIMing:FETCh:DELay? ‘identifier’
Input
Parameters
‘identifier’: Specify the measurement name.
Description This command returns the currently set delay sweep in seconds. The delay
sweep is set using the :INPut:DELay command. After setting the value, a
data center alignment is executed followed by an output timing
measurement.
This SCPI is applicable for M8041A, M8051A, M8062A and M8046A.
Example :PLUG:OTIM:FETC:DEL? ‘Output Timing 1’
(“M1.DataIn1”,4.879243000000001E-009)