226 Keysight M8070A Programming Guide
5 SCPI Command Reference
:OUTPut:TRIGger:MODE[?]
Syntax :OUTPut:TRIGger:MODE ‘identifier’, <CLOCk|SEQuencer>
:OUTPut:TRIGger:MODE? ‘identifier’
Input
Parameters
‘identifier’: 'M1.TrigOut'
<CLOCk|SEQuencer>: Set the operating mode of the trigger out.
Return Range CLOC|SEQ
Description This command sets the operating mode of the trigger out (TRIG OUT)
either to subrate clock or sequencer controlled mode.
This SCPI is applicable for M8041A and M8045A.
Example :OUTP:TRIG:MODE ‘M1.TrigOut’, CLOC
:OUTPut:TRIGger:DIVider[?]
Syntax :OUTPut:TRIGger:DIVider ‘identifier’, <NRf>
:OUTPut:TRIGger:DIVider? ‘identifier’
Input
Parameters
‘identifier’: 'M1.TrigOut'
<NRf>: Set the divider factor for the trigger out.
Return Range 2 to 65535
Description This command sets the divider factor of the trigger out when the subrate
clock operating mode is selected.
This SCPI is applicable for M8041A and M8045A.
Example :OUTP:TRIG:DIV ‘M1.TrigOut’, 8

Table of Contents

Other manuals for Keysight Technologies J-BERT M8020A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies J-BERT M8020A and is the answer not in the manual?

Keysight Technologies J-BERT M8020A Specifications

General IconGeneral
BrandKeysight Technologies
ModelJ-BERT M8020A
CategoryControl Unit
LanguageEnglish

Related product manuals