274 Keysight M8070A Programming Guide
5 SCPI Command Reference
:FETCh:IBERate?
Syntax :FETCh:IBERate? ‘identifier’
Input
Parameters
‘identifier’: 'M*.DataIn1' or 'M*.DataIn2'
Description This query returns the instantaneous bit error rate measured by the
addressed error detector. The response contains a timestamp, the location
and the measured BER.
(TimeStamp, “Location”, BER[, coding specific ratios])
Timestamp: As timestamp the Unix epoch time is used; it is defined as
elapsed seconds, milliseconds etc., since 01.01.1970 UTC.
Location: It is a string referred to the place the ratios are located. This
parameter is important if a group name is used as ‘Identifier’.
BER: The instantaneous bit error ratio.
Additional counters for 8b10b coding:
•SymbolErrorRatio
IllegalSymbolRatio
DisparityErrorRatio
FillerSymbolRatio
FrameErrorRatio
Additional Ratios for 128/130 and 128/132 coding:
BlockErrorRatio:
FillerSymbolRatio:
FrameErrorRatio:
Additional Counters for PAM-4 line coding
Symbol Error Ratio
Symbol0 Error Ratio
Symbol1 Error Ratio
Symbol2 Error Ratio
Symbol3 Error Ratio
This query returns the present state.
This SCPI is applicable for M8041A, M8051A, M8061A, M8062A and
M8046A.

Table of Contents

Other manuals for Keysight Technologies J-BERT M8020A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies J-BERT M8020A and is the answer not in the manual?

Keysight Technologies J-BERT M8020A Specifications

General IconGeneral
BrandKeysight Technologies
ModelJ-BERT M8020A
CategoryControl Unit
LanguageEnglish

Related product manuals