424 Keysight M8070A Programming Guide
5 SCPI Command Reference
Example The following example stops a parameter sweep measurement with the
measurement name identifier called ‘ParameterSweep1’:
:PLUG:PSWE:STOP ‘ParameterSweep1’
:PLUGin:PSWEep:ACQuisition Subnode
This subnode has the following SCPI structure:
:ALOCation[?]
:COMPared[?]
:ACQuisition
:SFRom[?]
:SLOCation[?]
:SMODe[?]
:SRTime[?]
:STEP[?]
:STO[?]
:SWPArameter[?]

Table of Contents