EasyManua.ls Logo

Keysight Technologies J-BERT M8020A

Keysight Technologies J-BERT M8020A
502 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Keysight M8070A Programming Guide 475
SCPI Command Reference 5
:DATA:PATTern:CATalog?
Syntax :DATA:PATTern:CATalog? <pattern-path>
Input
Parameters
<pattern-path>: Location of patterns.
Description This command returns a list of patterns found at the specified path.
Example :DATA:PATT:CAT? "factory:XAUI"
“CJPAT_bit,CRPAT_b8b10,CRPAT_bit”
:DATA:PATTern:CINFormation?
Syntax :DATA:PATTern:CINFormation?
<symbol-coding>[,<mask-used>[,<squelch-used>]]
Input
Parameters
<symbol- coding>: BIT|B8B10|B128B130|B128B132 for bit coding, 8b10b
coding, 128/130 coding or 128/132 coding.
<mask- used>: 0|1|OFF|ON to specify if mask attribute is used. Default is
OFF. Not using mask is mostly useful for bit coding to save space.
<squelch-used>: 0|1|OFF|ON to specify if squelch attribute is used. Default
is OFF. Not using squelch is mostly useful for bit coding to save space.
Return Range <symbol-coding>, <mask-used>, <squelch-used>
Description This command returns coding information.
Example :DATA:PATT:CINF? b8b10,on,on
16,"Data",0,7,"K/D",8,8,"Mask",10,10,"Squelch",11,11,"Enable
Scrambler",12,12,"Pause Scrambler",13,13,"Reset
Scrambler",14,14,"Start of Frame",15,15

Table of Contents