l Fast transient response - Available on Keysight N675xA, N676xA, and N678xA SMU power mod-
ules. Transient response is less than 100 μs.
l Output autoranging capability - Available on Keysight N676xA and N675xA power modules. Autor-
anging supplies the maximum rated power over a continuous range of voltage and current settings
l Output On/Off sequencing - A turn-on/turn-off delay capability for each output allows output
on/off sequencing.
l Front panel binding posts + and – output and + and – sense terminals are provided for each out-
put. Sense terminals provide 4-wire voltage measurements.
l Output protection - Each output has over-voltage, over-current, and over-temperature protection.
Over-voltage and over-current protection are programmable.
l Emergency shut-off + and – output and + and – sense terminals are provided for each output.
Sense terminals provide 4-wire voltage measurements.
l Multiple-Quadrant operation - Available on Keysight N678xA SMU and N6783A power modules.
2- quadrant operation provides source and sink output capability. Keysight model N6784A offers
4- quadrant output operation.
Measurement features
l Multiple-output/Single-output meter display - Switch between a 4-output summary view and a 1-
output detailed view of power analyzer information. All power modules display real-time output
voltage and current measurements as well as status information.
l Scope-like display - Voltage and/or current waveforms of all outputs can be simultaneously dis-
played. Adjustable markers provide calculated measurements.
l Data logging display - Average, minimum, and maximum voltage and current values can be logged
over an extended time period to the display. Adjustable markers provide calculated meas-
urements.
l Measurement functions - Average, minimum, and maximum values are provided for all voltage
and current measurements. Output power (Watts) is calculated for all outputs in single-output
meter view.
l Seamless measurement autoranging - Available on Keysight N6781A, N6782A, N6785A, and
N6786A SMU power modules. Output measurements seamlessly autorange between ranges –
however, the 10 μA current range must be selected manually.
l Microampere current measurements - Available on Keysight N6761A, N6762A, and N678xA SMU
power modules. Current measurement can be made as low as 1 μA in the 10 μA range.
l Fast Digitizing Available on Keysight N678xA SMU power modules. 5.12 μs/sample for one para-
meter; 10.24 μs/sample for two parameters.
l Histogram measurement - Available on Keysight N6781A N6782A, N6785A, and N6786A SMU
power modules. Provides a statistical measurement for profiling the measured current.