Parameter Typical Return
DWELl | TRIGgered, *RST DWELl DWEL or TRIG
Step 0 - 99, *RST 0 (none)
Specify trigger pacing for sequence step 1: ARB:SEQ:STEP:PAC TRIG, 1, (@1)
l If the <step#> specified is an existing sequence step, that step will be changed to the specified
waveshape with all parameters reset to default values.
l New sequence steps must be specified sequentially. To create a new sequence step, <step#>
should be specified to be the current length of the sequence (see
[SOURce:]ARB:SEQuence:LENgth?). When a step is added, all parameters of the step waveform
are reset to their default values.
[SOURce:]ARB:SEQuence:TERMinate:LAST <Bool>, (@<chanlist>)
[SOURce:]ARB:SEQuence:TERMinate:LAST? (@<chanlist>)
Determines the output value when the Arb sequence terminates. The state is either ON (1) or OFF (0).
When
ON
The outputvoltageor current remains atthe last Arb sequence value. The last voltage or currentArb value becomes the IMMediate
valuewhen the sequence completes.
When
OFF
The outputreturns to the settings that werein effect before the sequence started. This also applies when the sequence is aborted,
Parameter Typical Return
0|OFF|1|ON, *RST Off 0or1
Sets the sequence to terminate with the voltage or current set at the last sequencevalue:
ARB:SEQ:TERM:LAST ON,(@1)
l The query returns 0 if the output returns to the settings that were in effect before the sequence
started, and 1 if the output voltage or current remains at the last sequence value.
7 SCPI Programming Reference
266 Keysight N6705C Operating and Service Guide