Delay Offset Manually specifying a delay offset lets you configure longer turn-on delays than the
automatically calculated delay offset. This is useful if you are sequencing turn-on/turn-off delays
across multiple mainframes as discussed under Output Couple Controls. Also, if you are using the
scope to view the output sequence, you may choose longer turn-on delays to make the internal delay
offset line up with the grid on the display. Note however, that if you program a shorter delay than the
automatic delay offset, you may experience improper synchronization across all outputs.
Max delay offset for this frame - This field displays the maximum delay offset required for all the power
modules that are installed in the power analyzer.
Step 4 Use the All Outputs On and Off keys:
Once output delays have been set, use the All Outputs On key to start the On delay sequence. Use the
All Outputs Off key to start the Off delay sequence.
The All Outputs On/Off keys will turn ALL outputs on or off, whether they are configured
to participate in an output on/off delay sequence or not.
From the remote interface:
To program turn-on and turn-off delays for channels 1 through 4:
OUTP:DEL:RISE 0.01,(@1)
OUTP:DEL:RISE 0.02,(@2)
OUTP:DEL:RISE 0.03,(@3)
OUTP:DEL:RISE 0.04,(@4)
OUTP:DEL:FALL 0.04,(@1)
OUTP:DEL:FALL 0.03,(@2)
OUTP:DEL:FALL 0.02,(@3)
OUTP:DEL:FALL 0.01,(@4)
To only include outputs 1 and 2 in a sequence and specify a different delay offset:
OUTP:COUP:CHAN 1,2
OUTP:COUP:DOFF:MODE MAN
OUTP:COUP:DOFF 0.050
To query the delay offset of the slowest power module in the mainframe (the maximum delay offset) in
seconds:
OUTP:COUP:MAX:DOFF?
To turn on two coupled outputs in a sequence:
OUTP ON,(@1:2)