Keysight Technologies N9040B UXA Signal Analyzer Service Guide 125
Instrument Messages
Condition Messages
217 7 Demod Error E This error is normally generated because of
one of the following reasons:
1. There is no carrier signal.
2. Walsh channels other than the pilot are
active.
3. There is some other modulation problem
that will prevent the measurement from
being made.
This problem must be corrected before the
measurement can continue.
cdma 2000 & W-CDMA: Cannot correlate to
the input signal and no active channel is
found. (from composite EVM measurement)
An active channel must meet the default
threshold criteria that it is within 20 dB of
the highest power code channel. The
threshold can be changed using the active
set threshold function in the Meas Setup
menu.
cdmaOne: A correlation failure with the pilot
CDMA channel occurred during
synchronous demodulation.
1xEV-DO: Cannot correlate to the input
signal and no active channel is found. (from
composite EVM measurement) An active
channel must meet the default threshold
criteria that it is within 20 dB of the highest
power code channel. The threshold can be
changed using the active set threshold
function in the Meas Setup menu.
In the PSA, this error was reported as one of
the following error numbers: 10872, 10962,
13070, 10228, 10768
217 7 Demod Error;Can’t
correlate
E Cannot correlate to the input signal and no
active channel is found. (from composite
EVM measurement) An active channel must
meet the default threshold criteria that it is
within 20 dB of the highest power code
channel. The threshold can be changed
using the active set threshold function in the
Meas Setup menu.
217 7 Demod Error;Data
interval too short
E There are not enough input I/Q pairs for the
measurement calculation. This may be
caused by an incorrect data capture.