428 Keysight Technologies N9040B UXA Signal Analyzer Service Guide
Assembly Replacement Procedures
A27 H1G Assembly (Option H1G)
Figure 15-76 Rear Brace Removal
7. Locate the H1G assembly and use the board extractor handles to loosen
the board slightly and allow access to the coax cables attached to the
board.
8. Refer to Figure 15-77.Remove the snap-in cables from the board
assembly. Leave the blue cables attached for removal later.
Figure 15-77 Early H1G Assembly