22
Unite
®
Panel System - Electrical Installation
Assembly Instructions
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Horizontal 10-Wire
Panel-to-Panel Jumpers
Note: Horizontal in-line 10-wire
panel-to-panel jumpers pass
power between 10-wire rigid
wireways, from one panel frame
to another. “In-Line (INL)
Panel-to-Panel Jumpers” are
12” in length and are for in-line
panel-to-panel connections only.
“Intersection (INT) Panel-to-Panel
Jumpers” are 15
1
/
2
” long and
are used for panel-to-panel
conditions at intersections
(90°,120°, or 180°).
1. At the location specified for a
horizontal "intersection" 10-wire
jumper, route the panel-to-panel
jumper through the holes in
the vertical posts between the
panel frames, then plug the ends
into each 10-wire rigid wireway
(Figures 3 through 9).
Figure
3-Horizontal In-Line 10-Wire Panel-to-Panel Jumper,12 Length
(2-Way 180°, In-Line Panel Frames shown)
10-wire rigid
wireways
10-wire rigid
wireways
in-line 10-wire
panel-to-panel
jumper (horizontal)
(12” length)
in-line 10-wire
panel-to-panel
jumper (horizontal)
(12” length)
Figure
4-Horizontal Intersection 10-Wire Panel-to-Panel Jumper, 15 / Length
(2-Way 180°, In-Line Panel Frames with 3 / Module Spacers shown)
1
2
1
2
10-wire rigid
wireways
10-wire
rigid
wireways
intersection 10-wire
panel-to-panel
jumper (horizontal)
(15 /”length)
1
2
intersection 10-wire
panel-to-panel
jumper (horizontal)
(15 /”length)
1
2

Table of Contents