TECHNICAL INFORMATION
2
41
EN
2.15.4 Electric pump (optional)
N
OTE:
Component not necessarily supplied by
KOHLER.
T
he electric pump is located before the fuel filter. One of
the following pumps can be assembled
A1 - A2 - A3 - A4.
Tab. 2.34 a-b-c-d
indicates the pumps' features.
POS.
DESCRIPTION
1
Electrical connection
2
Prefilter pump
IN
Ingoing fitting (IN) from tank
OUT
Outgoing fitting (OUT) to fuel filter
Tab 2.34a
A1
VALUE
Voltage
12 - 24 V
Delivery
100 L/h @ 0.44 - 0.56 bar
Tab 2.34b
A2
VALUE
Voltage
12 V
Delivery
60.56 L/h @ 0.41 bar
Tab 2.34c
A3
VALUE
Voltage
12 V
Delivery
24 L/h @ 0.1 bar
Tab 2.34d
A4
VALUE
Voltage
12 V
Delivery
30 L/h @ 0.4 bar
Fig 2.34