Maintenance 18
Lubricating the universal shaft 18.3
Comprima F 155
Original Operating Instructions 150001049_01_en 185
Every 50 operating hours
(2)
18.3 Lubricating the universal shaft
RP000-176
ü The machine is shut down and safeguarded, refer to page27.
Observe operating instructions of the universal shaft manufacturer.
Clean the universal shaft.
Lubricate the universal shaft with multi-purpose grease at the intervals indicated in the table
below.
For a list of the lubricating greases to be used, refer to page43.
The following table provides information about the lubricant quantity and the lubrication interval
per lubrication point.
Pos. Lubricant quantity Lubrication interval
(1) 18 g 50 hours
(2) 30 g
(3) 20 g
(4) 6 g
18.4 Tightening torques
Deviating tightening torques
All screw connections must in general be tightened with the listed tightening torques following.
Deviations from the tables are marked accordingly.