19.4 Malfunctions on the chain lubrication unit
Malfunction: The oil consumption is too low.
Possible cause Remedy
The nozzles of the central
chain lubrication are soiled so
that the oil pump pressure is
too low.
Clean the dosing units of the central chain lubrication
system, refer to page207.
Clean the oil pump, refer to page206.
The pressure is too low, as
the oil pump is not pressed in
for the complete stroke.
Increase the oil quantity, refer to page206.
Have the oil pump dismounted and cleaned or replaced by a
KRONE service partner.
The oil is too thick.
Use recommended oil, refer to page43.
The central chain lubrication
system is contaminated.
Clean the entire central chain lubrication system.
Malfunction: The oil consumption is too high.
Possible cause Remedy
The main tube is torn.
Have the main tube repaired or replaced changed by a
KRONE service partner.
The oil is too thin.
Use recommended oil, refer to page43.
Malfunction: The machine is dry.
Possible cause Remedy
There is no pressure. The oil
pump is not functioning.
Have the oil pump dismounted and cleaned or replaced by a
KRONE service partner.
There is no pressure. The
main tube is torn.
Have the main tube repaired or replaced changed by a
KRONE service partner.
There is no pressure. The
system has no oil.
Vent the chain lubrication unit, refer to page206.
The system is blocked, as the
main tube is jammed.
Have the main tube repaired or replaced changed by a
KRONE service partner.
Malfunction: The oil pump is not pressed for the complete stroke.
Possible cause Remedy
The dosing units are blocked.
Cleaning the dosing units, refer to page207.
The oil is too thick.
Use recommended oil, refer to page43.