Technical data 5
Consumables 5.1
Comprima F 155
Original Operating Instructions 150001049_01_en 43
Minimum requirements for the tractor
Minimum oil quality Oil ISO VG 46
Delivery capacity hydraulics (min.) 30 L/min
Delivery capacity hydraulics (max.) 60 L/min
Electrical connections
Electr. connection for road travel lighting (7-pole plug) 12 volts
Electr. connection for operation (3-pole plug) 12 V (for "medium electronics"
version)
Electr. connection for operation (ISOBUS socket) available
Necessary hydraulic connections at the tractor
Hydraulic connection (T)/depressurised return in the tank 1 x
Single-acting hydraulic connection 2 x
For version with "Hydraulic support jack"
Double-acting hydraulic connection
1 x
Tyre designation Minimum pres-
sure
V
max
=10km/h
Maximum pres-
sure
Recommended tyre pressure
1
Single axle Tandem axle
Guide wheels on the pick-up
15x6.00-6 3.2 bar
Tyres on the machine
15.0/55-17 1.3 bar 3.6 bar 2.6 bar 1.5 bar
500/50-17 1.0 bar 2.8 bar 2.0 bar 1.5 bar
500/55-20 1.0 bar 3.0 bar 1.5 bar 1.5 bar
1
This recommendation applies especially to the typical mixture of operation (field/road) at the
maximum permitted machine speed. If required, the tyre pressure can be reduced to the
indicated minimum air pressure. However, the associated maximum speed must then be
observed.
Airborne noise emission
Emissions value (sound pressure level) 72.8 dB
Measurement device Bruel & Kjaer, Type 2236
Accuracy class 2
Measurement uncertainty (according to DINENISO11201) 4 dB
Ambient temperature
Temperature range for machine operation -5 to +45 °C
5.1 Consumables
NOTICE
Complying with change intervals for biooils
To ensure high life expectancy of the machine, it is absolutely necessary to comply with
change intervals for biooils due to the ageing of the oils.