18 Maintenance
18.22 Servicing compressed air brake (for version with "Compressed air brake")
208
Comprima F 155
Original Operating Instructions 150001049_01_en
18.21.3 Replacing the hose on the dosing unit
RP000-232
If hoses(4) on the dosing units(2) are damaged, they must be replaced.
ü The machine is shut down and safeguarded, refer to page27.
ü The front side hood is open.
Unscrew the cap nut(1) from the dosing unit(2).
Cut through the hose(4) above the cap nut(1).
ð The hose(4) is shortened with each cut. Therefore, do not cut any further than the
piece which is damaged.
Pull the defective hose(4) out of the cap nut(1) and dispose of.
Screw the cap nut(1) onto the dosing unit(2) hand-tight.
Insert the new end of the hose(4). Ensure that the hose(4) has been completely inserted
into the cap nut(1).
18.22 Servicing compressed air brake (for version with "Compressed air
brake")
18.22.1 Cleaning air filter
3
4
5
6
7
2
8
1
RP000-436
1 Air filter complete 5 Spring
2 Spring 6 Seal ring
3 Filter element 7 Cover cap
4 Spacer 8 Clasp locking ring
The air filters(1) clean the compressed air and guard the compressed air brake from
malfunctions. The compressed air brake remains functional in both directions of flow even when
a filter element(3) is blocked.