EasyManua.ls Logo

Krone Big Pack 890 HS - Menu 4-2 Manual Sensor Test

Krone Big Pack 890 HS
324 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
KRONE ISOBUS-Terminal CCI 100
123
Pos: 24.96 /BA/Inf o-Center/CC-ISOBUS- Terminal/CCI-Bi G Pack/Hauptmenüs/Haupt menü 4 Service/Menü 4-2 Sensor test Hand @ 44\mod_1275483 833375_78.doc @ 391921
7.12.1 Menu 4-2 „Manual sensor test“
BPK40190_1
4-2
CC000040
4-2
1
B1
B2
Fig. 78
In the manual sensor test, the sensors that are installed on the machine are checked for errors.
In addition, the sensors can be correctly adjusted in the manual sensor test. There is no
guarantee the machine is working correctly until after the sensors have been adjusted.
Caution!
The P.T.O. shaft must not be turning during the sensor test.
Calling the menu
Main menu 4 "Service" is called.
You can select menu 4-2
by pressing function key or . The symbol is shown in
reverse colors
Press the rotary potentiometer
Press function key
Selecting the sensor
Select the sensor by pressing the function key
or
The selected sensor is displayed inversely and is tested.
Pos: 24.97 /BA/Inf o-Center/Schwader/Bedi eneinheit - Komfor t/Swadro 1400/Hauptmenüs/ Hauptmenü 4 Servic e/Einstellwerte Sensor allgemeiner Text @ 6\ mod_1215416779856_78. doc @ 101137
Setting values:
The minimum and maximum setting values with the sensor alive (metal in front of the sensor)
are shown in the upper part of the bar display. The current setting value (actual value) is
displayed under the bar display.
The distance from the sensor to the metal must be adjusted so that in the alive state the bar is
in the upper mark. Next check whether the bar is in non-alive state in the lower marked area.
Pos: 24.98 /BA/-----Seitenumbruch------ @ 0\mod_1196175311226_ 0.doc @ 4165