Maintenance – lubrication
270
Pos: 34.60 /Überschri ften/Überschri ften 3/A-E/Einstell ung der Sensoren @ 0\mod_1199962 173428_78.doc @ 37635
13.8.1 Adjusting the Sensors
Pos: 34.61 /BA/W artung/Sensoren/Namursen sor d = 08 mm @ 24\mod_124177031236 9_78.doc @ 248607
13.8.1.1 Namur sensor d = 8 mm
a
BP-VFS-088-1
2
1
3
Figure 195:
The dimension between the encoder (2) and the sensor (1) must be "a" = 0,5 mm .
Setting
Loosen the nuts on either side of the sensor.
Turn the nuts until dimension "a" = 0,5 mm is reached.
Tighten the nuts again.
Pos: 34.62 /BA/W artung/Sensoren/Namursen sor d = 12 mm @ 0\mod_1199962247038 _78.doc @ 37654
13.8.1.2 Namur sensor d = 12 mm
a
BP-VFS-088-1
2
1
3
Figure 196
The dimension between the encoder (2) and the sensor (1) must be "a" = 2 mm .
Setting
Loosen the nuts on either side of the sensor.
Turn the nuts until dimension "a" = 2 mm is reached.
Tighten the nuts again.
Pos: 34.63 /BA/W artung/Sensoren/Namursen sor d = 30 mm @ 0\mod_1199962520100 _78.doc @ 37673