Malfunctions - Causes and Remedies
282
Pos: 38.20 /BA/Störunge n - Ursachen und Behebung/ Großpackenpressen/S törungen-Ursac hen-Behebung Doppelkn oter T1 @ 24\mod_1242027120 229_78.doc @ 249022
No
.
Malfunction Cause and/or remedy
1
Knotter tongue bends or frequent rupture of
the knotter tongue.
1.1
Cause:
Second knot remains hanging on the knotter
tongue.
Remedy:
See no.2
2 Knot remains hanging on the knotter hook.
2.1
Cause:
Worn or rough spots on the knotter hook or bent
knotter hook or knotter tongue.
Remedy:
Check lower twine path and correct, if and when
necessary.
2.2
Cause:
Not enough twine tension on the lower twine
strand.
Remedy:
Tighten the twine brake (1) by:
• tightening the spring (2) by about one to two turns
of the winged nut (3)
• removing any dirt deposits in all twine eyes (4), the
twine brake (1) and on the swing angle (7)
• replace broken springs (2), twine tension springs
(5) or worn twine eyes (4)
• replace broken or worn brake wheels (6)
2.3
Cause:
Holding force of the twine retainer is too low.
BPXC0255
1
3
2
Remedy:
Readjust the twine retainer:
• Undo the counter nut (2)
• Ensure stronger pre-tensioning of the twine
retainer spring (3) with the screw (1) (approx. half
a turn)
• Tightening the counter nut (2)
Degrease the twine retainer