8: Device Ports
SLCâ„¢ 8000 Advanced Console Manager User Guide 177
3. Click the Add Site button.
To view or update a site:
1. In the Sites table, select the site and click the View Site button. The site attributes are
displayed in the bottom half of the page.
2. Update any of the site attributes.
3. Click the Edit Site button.
To delete a site:
1. Select the site in the Sites table.
2. Click the Delete Site button.
Configures a set of site-oriented modem parameters that can be activated by various modem-
related events (authentication, outbound network traffic for DOD connections, etc.).
The site parameters will override any parameters configuredfor the modem.
Uses sites with a modem, enable 'usesites'. Sites can be used with the following modem states:
dialin, dialback, cbcpserver, dialondemand, dialin+ondemand, and dialback+ondemand.
To create or edit a site:
set site add|edit <Site Name> [<parameters>]
Parameters
name <Site Name> (edit only)
deviceport <Device Port # or Name or none>
usbport <U1|U2>
internal modem
auth <pap|chap>
loginhost <User Login/CHAP Host>
localipaddr <negotiate|IP Address>
remoteipaddr <negotiate|IP Address>
routeipaddr <IP Address>
routemask <Mask>
routegateway <Gateway>
nat <enable|disable>
dialoutnumber <Phone Number>
dialoutlogin <User Login>
Modem Timeout Timeout for dial-in and dial-on-demand PPP connections. Select Yes (default) for
the SLC 8000 advanced console manager to terminate the connection if no traffic
is received during the configured idle time. Enter a value of from 1 to 9999
seconds. The default is 30 seconds.
Restart Delay The number of seconds after the modem timeout and before the SLC unit
attempts another connection. The default is 30 seconds.
CBCP Server
Allow No Callback
For a CBCP Server site, allows "No Callback" as an option in the CBCP
handshake in addition to User-defined Number and Admin-defined Number.
Enable NAT Select to enable Network Address Translation (NAT) for PPP connections.
Note: IP forwarding must be enabled on Network Settings (on page 54) for NAT
to work.

Table of Contents

Other manuals for Lantronix SLC 8000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix SLC 8000 and is the answer not in the manual?

Lantronix SLC 8000 Specifications

General IconGeneral
Rack mountingYes
Console portRJ-45
Serial ports quantity48
USB 2.0 ports quantity2
AC input voltage120-230 V
Power source typeAC
AC input frequency50 - 60 Hz
Weight and Dimensions IconWeight and Dimensions
Weight5030 g
Dimensions (WxDxH)436.9 x 304.8 x 43.18 mm