EasyManuals Logo
Home>Lantronix>Network Hardware>SLC 8000

Lantronix SLC 8000 User Manual

Lantronix SLC 8000
396 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #306 background imageLoading...
Page #306 background image
14: Application Examples
SLCâ„¢ 8000 Advanced Console Manager User Guide 306
5. Connect to the SUN Unix server using the direct command.
[SLC]> connect direct deviceport 2
SunOS 5.7
login: frank
Password:
Last login: Wed Jul 14 16:07:49 from computer
Sun Microsystems Inc.SunOS 5.7Generic October 1998
SunOS computer 5.7 Generic_123485-05 sun4m sparc SUNW,SPARCstation-20
$
6. Use the escape sequence to escape from direct mode back to the command line interface.
Local Serial Connection to Network Device via Telnet
This example shows a terminal device connected to an SLC device port, and a Sun server
connected over the network to the SLC device. When a connection is established between the
device port and an outbound Telnet session, users can access the Sun server as though they
were directly connected to it. (See Chapter 11: Connections on page 209).
Figure 14-4 Local Serial Connection to Network Device via Telnet
In this example, the sysadmin would:
1. Display the current settings for device port 2:
[SLC]> show deviceport port 2
___Current Device Port
Settings________________________________________________
Number: 2 Name: Port-2
Modem Settings-------------Data Settings-----------IP Settings-------
Modem State: disabled Baud Rate: 9600 Telnet: disabled
Modem Mode: text Data Bits: 8 Telnet Port: 2002
Timeout Logins: disabled Stop Bits: 1 SSH: disabled
Local IP: negotiate Parity: none SSH Port: 3002
Remote IP: negotiate Flow Control: xon/xoff IP: <none>
Authentication: PAP Logins: disabled
CHAP Host: <none> Break Sequence: \x1bB
CHAP Secret: <none> Check DSR: disabled
NAT: disabled Close DSR: disabled
Dial-out Login: <none>
Dial-out Password: <none>
Dial-out Number: <none>
Dial-back Number: usernumber
Initialization Script: <none>
Internet
Serial Cable
to Device Port 2
Sun UNIX Server
SLC 8000 Advanced Console Manager

Table of Contents

Other manuals for Lantronix SLC 8000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix SLC 8000 and is the answer not in the manual?

Lantronix SLC 8000 Specifications

General IconGeneral
Rack mountingYes
Console portRJ-45
Serial ports quantity48
USB 2.0 ports quantity2
AC input voltage120-230 V
Power source typeAC
AC input frequency50 - 60 Hz
Weight and Dimensions IconWeight and Dimensions
Weight5030 g
Dimensions (WxDxH)436.9 x 304.8 x 43.18 mm

Related product manuals