12: User Authentication
SLC™ 8000 Advanced Console Manager User Guide 246
2. Enter the following:
Enable Kerberos Displays selected if you enabled this method on the User Authentication page. If
you want to set up this authentication method but not enable it immediately, clear
the checkbox.
Note: You can enable Kerberos here or on the first User Authentication page. If
you enable Kerberos here, it automatically displays at the end of the order of
precedence on the User Authentication page.
Realm Enter the name of the logical network served by a single Kerberos database and a
set of Key Distribution Centers. Usually, realm names are all uppercase letters to
differentiate the realm from the Internet domain. Realm is similar in concept to an
NT domain.
KDC A key distribution center (KDC) is a server that issues Kerberos tickets. A ticket is a
temporary set of electronic credentials that verify the identity of a client for a
particular service.
Enter the KDC in the fully qualified domain format (FQDN). An example is
SLC.local.
KDC IP Address Enter the IPv4 or IPv6 address of the Key Distribution Center (KDC).
KDC Port Port on the KDC listening for requests. Enter an integer with a maximum value of
65535. The default is 88.
Use LDAP Indicate whether Kerberos should rely on LDAP to look up
user IDs and Group IDs. This setting is disabled by default.
Note: Make sure to configure LDAP if you select this option.
Custom Menu If custom menus have been created, you can assign a default custom menu to
RADIUS users.
Escape Sequence A single character or a two-character sequence that causes the SLC 8000
advanced console manager to leave direct (interactive) mode. (To leave listen
mode, press any key.)
A suggested value is Esc+A (escape key, then uppercase "A" performed quickly
but not simultaneously). You would specify this value as \x1bA, which is
hexadecimal (\x) character 27 (1B) followed by an A.
This setting allows the user to terminate the
connect direct command on the
command line interface when the endpoint of the command is
deviceport,
tcp, or udp.
See Key Sequences on page 183 for notes on key sequence precedence and
behavior.
Break Sequence A series of 1-10 characters users can enter on the command line interface to send
a break signal to the external device. A suggested value is Esc+B (escape key,
then uppercase “B” performed quickly but not simultaneously). You would specify
this value as \x1bB, which is hexadecimal (\x) character 27 (1B) followed by a B.
Enable for Dial-back Select to grant a user dial-back access. Users with dial-back access can dial into
the SLC 8000 advanced console manager and enter their login and password.
Once the SLC unit authenticates them, the modem hangs up and dials them back.
Disabled by default.
Dial-back Number The phone number the modem dials back on depends on this setting for the device
port. The user is either dialed back on a fixed number, or on a number that is
associated with the user’s login (specified here).
Data Ports The ports users are able to monitor and interact with using the connect direct
command. U1 and U2 denote the USB upper and lower ports on the front of the
SLC unit.
Listen Port
The ports users are able to monitor using the connect listen command.

Table of Contents

Other manuals for Lantronix SLC 8000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix SLC 8000 and is the answer not in the manual?

Lantronix SLC 8000 Specifications

General IconGeneral
Rack mountingYes
Console portRJ-45
Serial ports quantity48
USB 2.0 ports quantity2
AC input voltage120-230 V
Power source typeAC
AC input frequency50 - 60 Hz
Weight and Dimensions IconWeight and Dimensions
Weight5030 g
Dimensions (WxDxH)436.9 x 304.8 x 43.18 mm

Related product manuals