Table 1. General specifications (continued)
Specification
Description
installation depend upon a variety of factors, including the number of racks in the
installation; the size, materials, and configuration of the room; the noise levels
from other equipment; the room ambient temperature, and employee's location in
relation to the equipment. Further, compliance with such government regulations
depends on a variety of additional factors, including the duration of employees'
exposure and whether employees wear hearing protection. Lenovo recommends
that you consult with qualified experts in this field to determine whether you are in
compliance with the applicable regulations.
Environment
ThinkSystem SR670 V2 complies with ASHRAE Class A2 specifications. System
performance may be impacted when operating temperature is outside AHSARE A2
specification.
• Air temperature:
– Operating
– ASHARE Class A2: 10°C to 35°C (50°F to 95°F); the maximum ambient
temperature decreases by 1°C for every 300 m (984 ft) increase in altitude
above 900 m (2,953 ft).
– Server off: 5°C to 45°C (41°F to 113°F)
– Shipment/storage: -40°C to 60°C (-40°F to 140°F)
• Maximum altitude: 3,050 m (10,000 ft)
• Relative Humidity (non-condensing):
– Operating
– ASHRAE Class A2: 8% to 80%; maximum dew point: 21°C (70°F)
– Shipment/storage: 8% to 90%
• Particulate contamination
Attention: Airborne particulates and reactive gases acting alone or in
combination with other environmental factors such as humidity or temperature
might pose a risk to the server. For information about the limits for particulates and
gases, see “Particulate contamination” on page 8.
Note: The server is designed for standard data center environment and
recommended to be placed in industrial data center.
Chapter 1. Introduction 5