Get-PmemDisk | Remove-PmemDisk
d. Clear Platform Configuration Data (PCD) and Namespace Label Storage Area (LSA) with the following
ipmctl command (for both Linux and Windows).
ipmctl delete -pcd
Notes: See the following links to learn how to download and use impctl in different operating
systems:
Windows: https://datacentersupport.lenovo.com/us/en/videos/YTV101407
Linux: https://datacentersupport.lenovo.com/us/en/solutions/HT508642
2. Install the PMEMs back to the target system, and upgrade system firmware to the latest version without
entering Setup Utility.
3. If the problem persists, overwrite PMEMs with the following ndctl command.
ndctl sanitize-dimm --overwrite all
4. Monitor the overwrite status with the following command.
watch -n 1 “ipmctl show -d OverwriteStatus -dimm”
5. When seeing all PMEM OverwriteStatus=Completed, reboot the system and see if the problem persists.
Hard disk drive problems
Use this information to resolve issues related to the hard disk drives.
“Server cannot recognize a hard drive” on page 353
Server cannot recognize a hard drive
Complete the following steps until the problem is solved.
1. Verify that the drive is supported for the server. See
https://static.lenovo.com/us/en/serverproven/
index.shtml
for a list of supported hard drives.
2. Make sure that the drive is seated in the drive bay properly and that there is no physical damage to the
drive connectors.
3. Run the diagnostics tests for the SAS/SATA adapter and hard disk drives. When you start a server and
press F1, the Lenovo XClarity Provisioning Manager V3 interface is displayed by default. You can
perform hard drive diagnostics from this interface. From the Diagnostic page, click Run Diagnostic
Disk Drive Test.
Based on those tests:
If the adapter passes the test but the drives are not recognized, replace the backplane signal cable
and run the tests again.
Replace the backplane.
If the adapter fails the test, disconnect the backplane signal cable from the adapter and run the tests
again.
If the adapter fails the test, replace the adapter.
Monitor and video problems
Use this information to solve problems related to a monitor or video.
“Screen is blank” on page 354
“Screen goes blank when you start some application programs” on page 354
“The monitor has screen jitter, or the screen image is wavy, unreadable, rolling, or distorted” on page 354