EasyManua.ls Logo

Lenovo ThinkSystem SR670 V2 - Front I;O Module Replacement

Lenovo ThinkSystem SR670 V2
390 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 93. Installing the flash power module
a.
Align the flash power module with the holder hinge; then, rotate the other end of the module
inward until it is secured in the holder.
b.
Close the retaining latch.
c.
Insert the holder bracket into the PCIe riser.
d.
Fasten the screw to secure the holder bracket to the PCIe riser.
e.
Close the retention latch.
Step 2. Connect the cable to the corresponding RAID adapter.
After you finish
1. Reinstall the PCIe riser. See “Install a PCIe riser” on page 189.
2. Complete the parts replacement. See “Complete the parts replacement” on page 328.
Front I/O module replacement
Follow instructions in this section to remove or install the front I/O module.
Remove the front I/O module
Follow instructions in this section to remove the front I/O module.
About this task
Attention:
Read “Installation Guidelines” on page 121 and “Safety inspection checklist” on page 122 to ensure that
you work safely.
Power off the server and peripheral devices and disconnect the power cords and all external cables. See
“Power off the server” on page 14.
If the server is installed in a rack, slide the server out on its rack slide rails to gain access to the top cover,
or remove the server from the rack. See “Remove the server from rack” on page 124.
Watch the procedure. A video of the installation and removal process is available:
YouTube:
https://www.youtube.com/playlist?list=PLYV5R7hVcs-BXei6L6c05osQVLt4w5XYx
Youku: https://list.youku.com/albumlist/show/id_59636529
Procedure
150 ThinkSystem SR670 V2 Maintenance Manual

Table of Contents

Related product manuals