Note: The illustration shows the Four PCIe x16 slot switched PCIe distribution board.
Figure 193. Installing a GPU distribution board 8-DW GPU Model
Step 2. Connect the power and signal cables to the GPU distribution board.
After you finish
1. Reinstall the GPU adapters. See “Install a GPU adapter” on page 253.
2. Complete the parts replacement. See “Complete the parts replacement” on page 328.
GPU adapter link bridge replacement
Follow instructions in this section to remove and install a GPU adapter link bridge.
Remove a GPU adapter link bridge
Follow instructions in this section to remove a GPU adapter link bridge.
About this task
Important: Make sure you have a suction cup available for properly removing the GPU adapter link bridge.
Attention:
Read “Installation Guidelines” on page 121 and “Safety inspection checklist” on page 122 to ensure that
you work safely.
Power off the server and peripheral devices and disconnect the power cords and all external cables. See
“Power off the server” on page 14.
If the server is installed in a rack, slide the server out on its rack slide rails to gain access to the top cover,
or remove the server from the rack. See “Remove the server from rack” on page 124.