Technical data
Operation with increased rated power
Rated data for 400 V mains voltage
3
142
EDKVF9333V DE/EN/FR 7.2
9300 Rated output current at switching frequency Max. permissible output current at switching
frequency
1)
2/4 kHz 2/8 kHz
2)
2/4 kHz 2/8 kHz
2)
Type I
r
[A] I
r
[A] I
max
[A] I
max
[A]
EVF9321−xV 1.8 1.8 2.2 2.2
EVF9322−xV 3.0 3.0 3.7 3.7
EVF9323−xV 5.5 5.5 5.8 5.8
EVF9324−xV 9.2 9.2 10.5 10.5
EVF9325−xV 15.0 15.0 19.5 19.5
EVF9327−xV 43.0 43.0 48.0 48.0
EVF9328−xV 56.0 56.0 70.5 70.5
EVF9329−xV 66.0 66.0 89.0 89.0
EVF9330−xV 100 100 134 134
EVF9331−xV 135 135 165 165
EVF9332−xV 159 159 225 225
EVF9333−xV 205 205 270 270
Bold print = Lenze setting
1)
The currents apply to a periodic load change with an overcurrent time of maximally 1 minute and a base load time
of 2 minutes with maximally 75 % I
rated
2)
Power−optimised operation with automatic switching frequency reduction. During operation with increased rated
power, the switching frequency is reduced to 2 kHz.